High Silicon Cast Iron (HSCI) Anodes
Long-life anodes for Impressed Current Cathodic Protection (ICCP) systems.
Typical application: Groundbeds for pipelines, tanks and plant structures.
Products · Trade
We import and supply the following Cathodic Protection materials for EPC contractors and industrial projects in Saudi Arabia.
Long-life anodes for Impressed Current Cathodic Protection (ICCP) systems.
Typical application: Groundbeds for pipelines, tanks and plant structures.
Carbon backfill placed around ICCP anodes to lower resistance and extend anode life.
Typical application: Shallow and deep-well anode groundbeds.
Perforated pipe that lets gases produced at the anodes escape from the groundbed.
Typical application: Deep-well ICCP groundbeds.
Test coupon combined with a permanent reference electrode for accurate monitoring of CP levels.
Typical application: CP monitoring at test stations on pipelines.
Magnesium, zinc or aluminium anodes that protect steel without an external power source.
Typical application: Pipelines, tanks, marine and buried structures.
Hydrated gypsum, the main ingredient of prepackaged galvanic anode backfill, keeping anode output steady and consumption even.
Typical application: Magnesium and zinc anode backfill (typically 75% gypsum, 20% bentonite, 5% sodium sulphate).
Swelling sodium bentonite that absorbs and holds moisture, keeping the resistance between anode and soil low.
Typical application: Galvanic anode backfill, earthing systems and sealing of deep-well groundbeds.
Tell us your project requirements and we'll source it for you.
Supplied alongside our Cathodic Protection materials.
Stickers Reels
Packing Products
Plastic Products
| Product | Short description | Typical application |
|---|---|---|
| High Silicon Cast Iron (HSCI) Anodes | Long-life anodes for Impressed Current Cathodic Protection (ICCP) systems. | Groundbeds for pipelines, tanks and plant structures. |
| Coke Breeze Backfill | Carbon backfill placed around ICCP anodes to lower resistance and extend anode life. | Shallow and deep-well anode groundbeds. |
| Perforated Vent Pipe | Perforated pipe that lets gases produced at the anodes escape from the groundbed. | Deep-well ICCP groundbeds. |
| CP Coupon with Integrated Reference Electrode | Test coupon combined with a permanent reference electrode for accurate monitoring of CP levels. | CP monitoring at test stations on pipelines. |
| Sacrificial (Galvanic) Anodes | Magnesium, zinc or aluminium anodes that protect steel without an external power source. | Pipelines, tanks, marine and buried structures. |
| Gypsum Backfill | Hydrated gypsum, the main ingredient of prepackaged galvanic anode backfill, keeping anode output steady and consumption even. | Magnesium and zinc anode backfill (typically 75% gypsum, 20% bentonite, 5% sodium sulphate). |
| Bentonite | Swelling sodium bentonite that absorbs and holds moisture, keeping the resistance between anode and soil low. | Galvanic anode backfill, earthing systems and sealing of deep-well groundbeds. |
Need CP materials for your next EPC project?